SPEC: 25015

CSA TECK 90 1000V ALUMINUM POWER CABLE

1000V FT4 - Flame Retardancy Rating, Direct Burial, XLPE Insulation, Aluminum Interlocked Armour, Sunlight Resistant, -40ºC Min, 90ºC Max, Rated HL (Hazardous Locations)

Télécharger les spécifications de la catégorie
PDF Tableau Excel

Application & Features

For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, hazardous locations or direct buried. Résistant au soleil. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. AG14 - Acid Gas Compliance. Voltage 1000V CSA / 600V UL.

Spécifications

Pour plus d’informations, sélectionnez un ensemble de produits ci-dessous :
Cond. Dimensions Cond. Strands Diameter Over Conductor (in) (cm) Épaisseur de l’isolation (mils) (mm) Inner Jacket Thickness (mils) (mm) Diameter Over Armor (in) (cm) Drain Wire Épaisseur de la jaquette (mils) (mm) Approx. OD (in) (cm) Approx. Weight (lbs/1000') (kgs/km) Max Pull Tension (lbs) (kg) Min. Rayon de courbure (pouces) (centimètres)
More Options
500 KCMIL 500 KCMIL
34 34
0.735 1.87
90 2.29
60 1.52
1.530 3.89
13x12 13x12
55 1.40
1.640 4.17
1413 2103
3000 1360.78
11.4 28.96

* Strand count meets minimum number per ASTM

Cond. Dimensions DC Resistance at 25C (ohms/1000') (ohms/km) AC Resistance at 75C (ohms/1000') (ohms/km) Inductive Reactance (ohms/1000') (ohms/km)
More Options
500 KCMIL 500 KCMIL
0.035 0.05
0.044 0.07
0.039 0.06

* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.

Normes et références

  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA C22.2 N° 2556 / UL 2556 Méthodes de test des câbles
  • CSA HL - for Hazardous Locations rating
  • CSA SUN RES - for Sunlight Resistant rating
  • Test de résistance aux flammes sur chemin de câbles vertical IEEE 1202 FT4 (70 000 Btu/h)

Construction

  1. Conducteur : Class B compact stranded 8000 Series Aluminum ACM in accordance with ASTM B801.
  2. Isolation : Cross-Linked Polyethylene (XLPE)
  3. Grounding Conductors: Uninsulated copper grounding conductor
  4. Liaison/attache : Ruban magnétique
  5. Inner Jacket: Black Polyvinyl Chloride (PVC)
  6. Armor: Aluminum Interlocked Armour (AIA)
  7. Overall Jacket: Black PVC (optional colours available)

Ressources

Il n’existe aucune ressource téléchargeable pour ce produit.