Southwire mobile home feeder is intended for the connection of mobile homes to a supply of electricity where permanent wiring is required as specified in the National Electrical Code. Convient pour les applications en enfouissement direct à des températures de conducteur ne dépassant pas 90 °C. La tension nominale est de 600 volts.
Cond. Dimensions | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Épaisseur de l’isolation (mils) (mm) | Ground Size | Approx. OD (in) (cm) | Aluminum Weight (lbs/1000') (kgs/km) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
2 AWG 2 AWG
|
2 2
|
7 7
|
0.268 0.68
|
60 1.52
|
1x6 1x6
|
0.951 2.42
|
189 281
|
305 454
|
More Options |
2 AWG 2 AWG
|
2 2
|
7 7
|
0.268 0.68
|
60 1.52
|
1x4 1x4
|
0.951 2.42
|
226 336
|
353 525
|
More Options |
2/0 AWG 2/0 AWG
|
2 2
|
19 19
|
0.376 0.96
|
80 2.03
|
1x4 1x4
|
1.313 3.34
|
368 548
|
561 835
|
More Options |
2/0 AWG 2/0 AWG
|
2 2
|
19 19
|
0.376 0.96
|
80 2.03
|
1x1 1x1
|
1.313 3.34
|
455 677
|
681 1013
|
More Options |
4/0 AWG 4/0 AWG
|
2 2
|
19 19
|
0.474 1.20
|
80 2.03
|
1x4 1x4
|
1.552 3.94
|
563 838
|
795 1183
|
More Options |
4/0 AWG 4/0 AWG
|
2 2
|
19 19
|
0.474 1.20
|
80 2.03
|
1x2/0 1x2/0
|
1.552 3.94
|
723 1076
|
1002 1491
|
* Strand count meets minimum number per ASTM
Cond. Dimensions | Conductor Number | Min. Rayon de courbure (pouces) (centimètres) | Max Pull Tension (lbs) (kg) | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Allowable Ampacity Raceway 75C | Allowable Ampacity Raceway 90C | |
More Options |
2 AWG 2 AWG
|
2 2
|
3.8 9.65
|
796 361.06
|
0.267 0.40
|
0.321 0.48
|
0.045 0.07
|
90 90
|
100 100
|
More Options |
2 AWG 2 AWG
|
2 2
|
3.8 9.65
|
796 361.06
|
0.267 0.40
|
0.321 0.48
|
0.045 0.07
|
90 90
|
100 100
|
More Options |
2/0 AWG 2/0 AWG
|
2 2
|
6.6 16.76
|
1597 724.39
|
0.133 0.20
|
0.160 0.24
|
0.043 0.06
|
135 135
|
150 150
|
More Options |
2/0 AWG 2/0 AWG
|
2 2
|
6.6 16.76
|
1597 724.39
|
0.133 0.20
|
0.160 0.24
|
0.043 0.06
|
135 135
|
150 150
|
More Options |
4/0 AWG 4/0 AWG
|
2 2
|
7.8 19.81
|
2539 1151.67
|
0.084 0.13
|
0.100 0.15
|
0.041 0.06
|
180 180
|
205 205
|
More Options |
4/0 AWG 4/0 AWG
|
2 2
|
7.8 19.81
|
2539 1151.67
|
0.084 0.13
|
0.100 0.15
|
0.041 0.06
|
180 180
|
205 205
|
* Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.