RHINOFLEXTM Type G-G cable is a heavy-duty cable for use where flexibility and maximum protection is required. For use with all portable, temporary, and permanent power applications such as mobile or stationary mining equipment, shuttle cars, mobile drills, pumps, roof bolters, conveyors, and any portable power where equipment grounding is required, It is ideal for use anytime extra-durable, flexible cable is required. Convient aussi pour une immersion continue dans l’eau. Le conducteur de vérification de mise à la terre fournit une surveillance de sécurité de la mise à la terre. La légende estampée permet une identification facile des câbles. Testé à -50 °C pour les torsions et impacts à froid.
Cond. Dimensions | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Épaisseur de l’isolation (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground Check Size | Inner Jacket Thickness (mils) (mm) | Épaisseur de la jaquette (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
8 AWG 8 AWG
|
3 3
|
168 168
|
0.153 0.39
|
60 1.52
|
0.287 0.73
|
10 10
|
55 1.40
|
145 3.68
|
1.026 2.61
|
661 984
|
More Options |
6 AWG 6 AWG
|
3 3
|
133 133
|
0.198 0.50
|
60 1.52
|
0.336 0.85
|
10 10
|
55 1.40
|
95 2.41
|
1.050 2.67
|
789 1174
|
More Options |
4 AWG 4 AWG
|
3 3
|
259 259
|
0.235 0.60
|
60 1.52
|
0.388 0.99
|
10 10
|
60 1.52
|
95 2.41
|
1.190 3.02
|
1014 1509
|
More Options |
2 AWG 2 AWG
|
3 3
|
308 308
|
0.302 0.77
|
60 1.52
|
0.452 1.15
|
8 8
|
65 1.65
|
90 2.29
|
1.325 3.37
|
1413 2103
|
More Options |
2/0 AWG 2/0 AWG
|
3 3
|
324 324
|
0.400 1.02
|
80 2.03
|
0.594 1.51
|
8 8
|
85 2.16
|
100 2.54
|
1.636 4.16
|
2401 3573
|
More Options |
4/0 AWG 4/0 AWG
|
3 3
|
532 532
|
0.550 1.40
|
80 2.03
|
0.751 1.91
|
8 8
|
80 2.03
|
135 3.43
|
2.040 5.18
|
3715 5529
|
More Options |
250 KCMIL 250 KCMIL
|
3 3
|
608 608
|
0.682 1.73
|
100 2.54
|
0.816 2.07
|
8 8
|
100 2.54
|
120 3.05
|
2.390 6.07
|
4386 6527
|
More Options |
350 KCMIL 350 KCMIL
|
3 3
|
855 855
|
0.809 2.05
|
100 2.54
|
0.926 2.35
|
8 8
|
100 2.54
|
125 3.18
|
2.680 6.81
|
5801 8633
|
Cond. Dimensions | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Puissance nominale (lbs) (kg) | Min. Rayon de courbure (pouces) (centimètres) | Allowable Ampacity In Air 90C | |
More Options |
8 AWG 8 AWG
|
0.715 1.06
|
0.903 1.34
|
0.036 0.05
|
112 50.80
|
8.2 20.83
|
59 59
|
More Options |
6 AWG 6 AWG
|
0.450 0.67
|
0.568 0.85
|
0.034 0.05
|
179 81.19
|
8.4 21.34
|
79 79
|
More Options |
4 AWG 4 AWG
|
0.282 0.42
|
0.356 0.53
|
0.033 0.05
|
285 129.27
|
9.5 24.13
|
104 104
|
More Options |
2 AWG 2 AWG
|
0.179 0.27
|
0.226 0.34
|
0.031 0.05
|
453 205.48
|
10.6 26.92
|
138 138
|
More Options |
2/0 AWG 2/0 AWG
|
0.090 0.13
|
0.114 0.17
|
0.030 0.04
|
910 412.77
|
13.0 33.02
|
215 215
|
More Options |
4/0 AWG 4/0 AWG
|
0.057 0.08
|
0.073 0.11
|
0.029 0.04
|
1447 656.35
|
16.3 41.40
|
287 287
|
More Options |
250 KCMIL 250 KCMIL
|
0.048 0.07
|
0.062 0.09
|
0.026 0.04
|
1710 775.64
|
19.1 48.51
|
320 320
|
More Options |
350 KCMIL 350 KCMIL
|
0.035 0.05
|
0.046 0.07
|
0.025 0.04
|
2394 1085.90
|
21.4 54.36
|
394 394
|
* Ampacities based upon ICEA S-75-381 Table H-1.
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.