RHINOPOWERTM Type MP-GC mine power feeder cable is a heavy-duty power cable for use in stationary horizontal HV mine power distribution circuits, for permanent or semi-portable applications with power transmission in deep mines, surface mines, open pits, tunnels, in conduit or duct (not to exceed max rated voltage), and suitable for direct burial in wet or dry locations. Veuillez consulter un spécialiste en installation d’usine pour les exigences relatives aux chutes verticales.
Cond. Dimensions | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Épaisseur de l’isolation (mils) (mm) | Diameter Over Insulation (in) (cm) | Ground Check Size | Épaisseur de la jaquette (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
4/0 AWG 4/0 AWG
|
3 3
|
19 19
|
0.474 1.20
|
115 2.92
|
0.738 1.87
|
8 8
|
140 3.56
|
2.120 5.38
|
3838 5712
|
More Options |
350 KCMIL 350 KCMIL
|
3 3
|
855 855
|
0.615 1.56
|
95 2.41
|
0.937 2.38
|
8 8
|
140 3.56
|
2.810 7.14
|
6453 9603
|
* Strand count meets minimum number per ASTM
Cond. Dimensions | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Capacitive Reactance (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Puissance nominale (lbs) (kg) | Min. Rayon de courbure (pouces) (centimètres) | Allowable Ampacity In Air 90C | |
More Options |
4/0 AWG 4/0 AWG
|
0.051 0.08
|
0.065 0.10
|
0.023 0.03
|
0.032 0.05
|
1447 656.35
|
25.4 64.52
|
321 321
|
More Options |
350 KCMIL 350 KCMIL
|
0.031 0.05
|
0.041 0.06
|
0.021 0.03
|
0.031 0.05
|
2394 1085.90
|
33.7 85.60
|
435 435
|
* Ampacities based upon ICEA S-75-381 Table I-1.
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.