Southwire’s Remote Power and Drill cord cable is a heavy-duty cable for use where limited flexing and rugged use are re- quired. For use in stationary heavy duty pumps or long-wall lighting application. Designed for long service life in wet or dry locations in underground mines. The cable is sunlight resistant, crush resistant, and abrasion resistant. Convient aussi pour une immersion continue dans l’eau. La légende estampée permet une identification facile des câbles.
Cond. Dimensions | Conductor Number | Cond. Strands | Diameter Over Conductor (in) (cm) | Épaisseur de l’isolation (mils) (mm) | Diameter Over Insulation (in) (cm) | Inner Jacket Thickness (mils) (mm) | Épaisseur de la jaquette (mils) (mm) | Approx. OD (in) (cm) | Approx. Weight (lbs/1000') (kgs/km) | |
More Options |
14 AWG 14 AWG
|
4 4
|
41 41
|
0.073 0.19
|
45 1.14
|
0.167 0.42
|
65 1.65
|
85 2.16
|
0.710 1.80
|
278 414
|
More Options |
12 AWG 12 AWG
|
5 5
|
65 65
|
0.094 0.24
|
45 1.14
|
0.184 0.47
|
65 1.65
|
100 2.54
|
0.830 2.11
|
398 592
|
More Options |
12 AWG 12 AWG
|
6 6
|
65 65
|
0.094 0.24
|
45 1.14
|
0.184 0.47
|
65 1.65
|
100 2.54
|
0.890 2.26
|
458 682
|
More Options |
10 AWG 10 AWG
|
5 5
|
104 104
|
0.117 0.30
|
45 1.14
|
0.205 0.52
|
65 1.65
|
95 2.41
|
0.900 2.29
|
492 732
|
More Options |
8 AWG 8 AWG
|
5 5
|
71 71
|
0.153 0.39
|
60 1.52
|
0.275 0.70
|
65 1.65
|
95 2.41
|
1.090 2.77
|
716 1066
|
Cond. Dimensions | DC Resistance at 25C (ohms/1000') (ohms/km) | AC Resistance at 75C (ohms/1000') (ohms/km) | Inductive Reactance (ohms/1000') (ohms/km) | Puissance nominale (lbs) (kg) | Min. Rayon de courbure (pouces) (centimètres) | Allowable Ampacity In Air 90C | |
More Options |
14 AWG 14 AWG
|
2.814 4.19
|
3.555 5.29
|
0.041 0.06
|
28 12.70
|
5.6 14.22
|
15 15
|
More Options |
12 AWG 12 AWG
|
1.774 2.64
|
2.241 3.33
|
0.037 0.06
|
44 19.96
|
6.6 16.76
|
20 20
|
More Options |
12 AWG 12 AWG
|
1.774 2.64
|
2.241 3.33
|
0.037 0.06
|
44 19.96
|
7.1 18.03
|
20 20
|
More Options |
10 AWG 10 AWG
|
1.111 1.65
|
1.404 2.09
|
0.035 0.05
|
70 31.75
|
7.2 18.29
|
25 25
|
More Options |
8 AWG 8 AWG
|
0.715 1.06
|
0.903 1.34
|
0.035 0.05
|
112 50.80
|
8.7 22.10
|
35 35
|
* Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.