SPEC: 25040

12-7 2/C CU XLP BLACK/WHITE TECK90 600V AIA BLACK PVC JKT

N° Southwire : 56179299

Télécharger les spécifications de la catégorie
PDF Tableau Excel
Sélectionnez les spécifications du produit
Construction
Couleur de la jaquette externe / l’armure
NOIR
Format

Application & Features

For exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet, dry, or hazardous locations. Résistant au soleil. Typical applications are for control. lighting and power circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants.

  • -40°C - CSA Cold Bend and Impact Temperature
  • -40°C - Min. Installation Temperature
  • 90°C - Max. Continuous Operating Temperature

Spécifications

Cond. Taille Calibre 12 AWG Calibre 12 AWG
Cond. Strands 7 7
Diameter Over Conductor (po) (cm) 0.088 0.22 po cm
Épaisseur de l’isolation (mils) (mm) 30 0.76 mils mm
Ground Size 1x14 1x14
Inner Jacket Thickness (mils) (mm) 50 1.27 mils mm
Diameter Over Armor (po) (cm) 0.605 1.54 po cm
Épaisseur de la jaquette (mils) (mm) 45 1.14 mils mm
Approx. OD (po) (cm) 0.695 1.77 po cm
Approx. Poids (lbs/1 000 pi) (kg/km) 222 330 lbs/1 000 pi kg/km
Max Pull Tension (lbs) (kg) 104 47.17 lbs kg
Min. Rayon de pliage (po) (cm) 4.8 12.19 po cm

* Use Table 5C in the 2015 Canadian Electrical Code to derate this ampacity as per Rules 4-004 & 12-2210
† Ampacities based on not more than 3 conductors (4 with neutral) in raceway or cable as per Table 2 of 2015 Canadian Electrical Code

Normes et références

  • ASTM B3 Soft or Annealed Copper Wire
  • Conducteurs en cuivre toronné à couche concentrique ASTM B8
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
  • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
  • CSA HL - for Hazardous Locations rating
  • CSA SUN RES - for Sunlight Resistant rating
  • CSA AG14 - Acid Gas Compliance
  • Test de résistance aux flammes IEEE 383 (70 000 btu)
  • Test de résistance aux flammes sur chemin de câbles vertical IEEE 1202 FT4 (70 000 Btu/h)

Construction

  1. Conducteur : Class B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.
  2. Isolation : Cross-Linked Polyethylene (XLPE), Colour Code: 2/C black, white; 3/C red, black, blue; 4/C red, black, blue, white; For 5/C cables or more, the insulation is black and numbered
  3. Grounding Conductors: Uninsulated Class B stranded grounding conductor
  4. Inner Jacket: Black Polyvinyl Chloride (PVC)
  5. Armor: Aluminum Interlocked Armour (AIA)
  6. Overall Jacket: Black PVC (optional colours available)

Ressources

Il n’existe aucune ressource téléchargeable pour ce produit.
Powered by Translations.com GlobalLink Web Software