SPEC: 25020

350-37 1/C CU TR-XLPE TECK90 5KV N/S 13X12 AIA ORANGE PVC JKT

N° Southwire : 58768099

Télécharger les spécifications de la catégorie
PDF Tableau Excel
Sélectionnez les spécifications du produit
Construction
Couleur de la jaquette externe / l’armure
ORANGE
Format

Application & Features

Southwire’s Teck 90, 5000V, non-shielded, TRXLPE insulated (treeing resistant) power cable is a CSA approved armoured cable for industrial and commercial medium voltage applications. FT4, -40C, HL , AG14 and 90°C rated for use in harsh Canadian environments. Rated for installation in cable trays, duct banks, direct burial, troughs, hazardous locations, continuous rigid cable supports, and is concrete encaseable.

  • -40°C - CSA Cold Bend and Impact Temperature
  • -25°C - Min. Installation Temperature
  • 90°C - Max. Continuous Operating Temperature
  • 140°C for Emergency Overload Temperature
  • 250°C for Short Circuit Temperature

Spécifications

Cond. Taille 350 KCMIL 350 KCMIL
Cond. Strands 37 37
Diameter Over Conductor (po) (cm) 0.661 1.68 po cm
Épaisseur de l’isolation (mils) (mm) 90 2.29 mils mm
Inner Jacket Thickness (mils) (mm) 60 1.52 mils mm
Diameter Over Armor (po) (cm) 1.511 3.84 po cm
Drain Wire 13x12 13x12
Épaisseur de la jaquette (mils) (mm) 55 1.40 mils mm
Approx. OD (po) (cm) 1.621 4.12 po cm
Approx. Poids (lbs/1 000 pi) (kg/km) 2033 3025 lbs/1 000 pi kg/km
Max Pull Tension (lbs) (kg) 2800 1270.06 lbs kg
Min. Rayon de pliage (po) (cm) 11.3 28.70 po cm

* Other conductor sizes and outer jacket colours are available upon request. (#s in brackets represent # of strands / conductor. Number of strands may vary as per CSA standard.)
** Non-Standard sizes are available upon request. Reel sizes are not guaranteed. The factory reserves the right to make changes as necessary to optimize manufacturing requirements.

Normes et références

  • ASTM B3 Soft or Annealed Copper Wire
  • Conducteurs en cuivre toronné à couche concentrique ASTM B8
  • CSA C22.2 No. 174 Cables in Hazardous Locations
  • CSA C22.2 No. 131 Type TECK 90 Cable
  • CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
  • CSA LTGG [-40°C] - as per C68.10 - for Cold Bend and Impact rating
  • CSA HL - for Hazardous Locations rating
  • CSA SUN RES - for Sunlight Resistant rating
  • CSA AG14 - Acid Gas Compliance
  • ICEA S-96-659 (NEMA WC 71) 2001-5000 V Câbles non-blindés
  • Test de résistance aux flammes IEEE 383 (70 000 btu)
  • Test de résistance aux flammes sur chemin de câbles vertical IEEE 1202 FT4 (70 000 Btu/h)
  • FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)

Construction

  1. Conducteur : Class B stranded copper, compressed or compact, in accordance with ASTM B3 and B8.
  2. Conductor Shield: Extruded semi-conducting thermosetting polymeric layer
  3. Isolation : TRXLPE (tree retardant cross linked polyethylene), Thickness: 0.090 inches (2.3 mm) - nominal, Insulation Level: 100% - ungrounded system, Temperature Rating: 90 °C
  4. Concentric Bonding Conductors: Class B, concentric bare copper wire serve
  5. Liaison/attache : Polypropylene tape
  6. Inner Jacket: Black PVC, Thickness: No. 2 AWG to No. 1/0 AWG = 0.045” (1.2 mm), No. 2/0 AWG to 1000 kcmil = 0.060” (1.6 mm)
  7. Armor: Aluminum Interlocked Armour (AIA)
  8. Overall Jacket: Orange PVC (optional colours available), Thickness: No. 2 AWG to 400 kcmil = 0.045” (1.2 mm), 500 kcmil to 1000 kcmil = 0.055” (1.4 mm)

Ressources

Il n’existe aucune ressource téléchargeable pour ce produit.
Powered by Translations.com GlobalLink Web Software